Viatris Pharmaceuticals Llc
This drug manufacturing facility is registered with the FDA by Viatris Inc.. ProPublica was able to identify at least 3 generic drugs that have been manufactured at this facility.
Facility Inspection History
The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.
The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.
When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.
- Jun 13, 2025Jun 13, 2025Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Dec 20, 2019Dec 20, 2019Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Mar 28, 2018Mar 28, 2018Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.5 citations
Handling and Storage to Prevent ContaminationThere was a failure to handle and store components at all times in a manner to prevent contamination.Following/documenting laboratory controlsEstablished laboratory control mechanisms are not followed and documented at the time of performance.Scientifically sound laboratory controlsLaboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Dec 8, 2016Dec 8, 2016Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Jul 2, 2015Jul 2, 2015Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.4 citations
Calibration/Inspection/Checking not doneRoutine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.Absence of Written ProceduresThere are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.Following/documenting laboratory controlsEstablished laboratory control mechanisms are not followed and documented at the time of performance.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Aug 20, 2013Aug 20, 2013Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.16 citations
Procedures not in writing, fully followedThe responsibilities and procedures applicable to the quality control unit are not in writing.Written procedures fail to includeWritten procedures for cleaning and maintenance fail to include maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for removal or obliteration of previous batch identification.Cleaning/maintenance records not keptRecords are not kept for the maintenance, cleaning, and inspection of equipment.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Sep 23, 2011Sep 23, 2011Inspection With Issues
The FDA ruled the facility was in an “unacceptable state of compliance.”
Inspectors found serious issues at the facility, and the agency ultimately recommended official compliance action. In cases like this, the FDA typically pauses the facility’s pending drug approvals. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public.9 citations
Cleaning / Sanitizing / MaintenanceEquipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.Written procedures not established/followedWritten procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.Control procedures to monitor and validate performanceControl procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Feb 8, 2010Feb 8, 2010Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.4 citations
Cleaning / Sanitizing / MaintenanceEquipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.Written procedures not established/followedWritten procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.Complaint Handling ProcedureProcedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.ProPublica was unable to locate a 483 form detailing issues found in this inspection.