Eo Products, Llc
This drug manufacturing facility is registered with the FDA by Eo Products, Llc.
Facility Inspection History
The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.
The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.
When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.
- Nov 17, 2020Nov 17, 2020Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.3 citations
Procedures not in writing, fully followedThe responsibilities and procedures applicable to the quality control unit are not in writing.Establish reliability of supplier's C of AEstablishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.Scientifically sound laboratory controlsLaboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Jan 16, 2015Jan 16, 2015Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.8 citations
Equipment Design, Size and LocationEquipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size, and suitably located to facilitate operations for its intended use.Reports of Analysis (Components)Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.Absence of Written ProceduresThere are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.ProPublica was unable to locate a 483 form detailing issues found in this inspection.