Eo Products, Llc

United States See location details

This drug manufacturing facility is registered with the FDA by Eo Products, Llc.

Facility Inspection History

The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.

Note: ProPublica does not provide medical advice. Stopping your medication, doctors warn, can be dangerous. Please consult your doctor first if you have concerns. Read more
2 Known Inspections

The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.

2 Inspections Found Issues

When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.

  • Nov 17, 2020
    Nov 17, 2020
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
    3 citations
    Procedures not in writing, fully followed
    The responsibilities and procedures applicable to the quality control unit are not in writing.
    Establish reliability of supplier's C of A
    Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
    Scientifically sound laboratory controls
    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
  • Jan 16, 2015
    Jan 16, 2015
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    8 citations
    Equipment Design, Size and Location
    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size, and suitably located to facilitate operations for its intended use.
    Reports of Analysis (Components)
    Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
    Absence of Written Procedures
    There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.