Amphastar Pharmaceuticals, Inc.
This drug manufacturing facility is registered with the FDA by Amphastar Pharmaceuticals, Inc.. ProPublica was able to identify at least 30 generic drugs that have been manufactured at this facility.
Facility Inspection History
The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.
The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.
When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.
- Apr 3, 2025Apr 3, 2025Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Mar 1, 2024Mar 1, 2024Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Jun 22, 2021Jun 22, 2021Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Nov 22, 2019Nov 22, 2019Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Nov 21, 2019Nov 21, 2019Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Jul 25, 2019Jul 25, 2019Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Mar 31, 2017Mar 31, 2017Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Aug 8, 2014Aug 8, 2014Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Mar 3, 2014Mar 3, 2014Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Feb 6, 2013Feb 6, 2013Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.3 citations
Establish reliability of supplier's C of AEstablishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.Scientifically sound laboratory controlsLaboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.Actual yield, % of theoretical yieldThe batch production and control records do not include a statement of the actual yield and percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Jun 28, 2012Jun 28, 2012Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.6 citations
Training--operations, GMPs, written proceduresEmployees are not given training in the particular operations they perform as part of their function.Investigations of discrepancies, failuresThere is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.Failure to submit ADE reportAdverse drug experience information has not been reported to FDA.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - May 6, 2011May 6, 2011Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Aug 19, 2009Aug 19, 2009Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors.2 citations
Items to cover on annual reviewsWritten procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.Records of disposition of rejected materialRecords do not include the disposition of rejected drug product containers.