Excelvision

This drug manufacturing facility is registered with the FDA by Excelvision.

Facility Inspection History

The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.

Note: ProPublica does not provide medical advice. Stopping your medication, doctors warn, can be dangerous. Please consult your doctor first if you have concerns. Read more
5 Known Inspections

The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.

5 Inspections Found Issues

When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.

  • May 7, 2025
    May 7, 2025
    Warning Letter

    The FDA issued a warning letter laying out significant issues.

    The letter is a disciplinary tool the FDA uses to lay out significant violations of manufacturing standards and to outline needed improvements. It often includes a summary of the steps the company had initially pledged to take to correct issues identified during inspections. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public.
  • Nov 19, 2024
    Nov 19, 2024
    Inspection With Issues

    The FDA ruled the facility was in an “unacceptable state of compliance.”

    Inspectors found serious issues at the facility, and the agency ultimately recommended official compliance action. In cases like this, the FDA typically pauses the facility’s pending drug approvals. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
  • Jul 7, 2023
    Jul 7, 2023

    An inspector documented issues at the facility.

    We were unable to connect this 483 form to an FDA inspection designation, but we do know that an inspector filed this form observing problem(s).
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
  • Oct 23, 2020
    Oct 23, 2020
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.
  • Dec 8, 2017
    Dec 8, 2017
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.
  • Feb 10, 2015
    Feb 10, 2015
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    4 citations
    Procedures not in writing, fully followed
    The responsibilities and procedures applicable to the quality control unit are not in writing.
    Procedures for sterile drug products
    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written.
    Lab controls established, including changes
    The establishment of specifications and test procedures including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.
  • Jul 19, 2012
    Jul 19, 2012
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.

Frequently Asked Questions