Aurobindo Pharma Limited
This drug manufacturing facility is registered with the FDA by Aurobindo Pharma Limited. ProPublica was able to identify at least 1102 generic drugs that have been manufactured at this facility.
Facility Inspection History
The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.
The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.
When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.
- May 10, 2022May 10, 2022Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.6 citations
Equipment Design, Size and LocationEquipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size, and suitably located to facilitate operations for its intended use.Computer control of master formula recordsAppropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.Absence of Written ProceduresThere are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Sep 27, 2019Sep 27, 2019Inspection With Issues
The FDA ruled the facility was in an “unacceptable state of compliance.”
Inspectors found serious issues at the facility, and the agency ultimately recommended official compliance action. In cases like this, the FDA typically pauses the facility’s pending drug approvals. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Jun 24, 2017Jun 24, 2017Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Mar 13, 2015Mar 13, 2015Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Jun 19, 2012Jun 19, 2012Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Jul 30, 2010Jul 30, 2010Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Oct 13, 2009Oct 13, 2009Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors.