Exela Pharma Sciences, Llc.
This drug manufacturing facility is registered with the FDA by Exela Pharma Sciences. ProPublica was able to identify at least 13 generic drugs that have been manufactured at this facility.
Facility Inspection History
The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.
The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.
When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.
- Jul 2, 2025Jul 2, 2025Warning Letter
The FDA issued a warning letter laying out significant issues.
The letter is a disciplinary tool the FDA uses to lay out significant violations of manufacturing standards and to outline needed improvements. It often includes a summary of the steps the company had initially pledged to take to correct issues identified during inspections. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public. - Nov 15, 2024Nov 15, 2024
An inspector documented issues at the facility.
We were unable to connect this 483 form to an FDA inspection designation, but we do know that an inspector filed this form observing problem(s).View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Jul 18, 2019Jul 18, 2019Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.7 citations
Environmental Monitoring SystemAseptic processing areas are deficient regarding the system for monitoring environmental conditions.Cleaning / Sanitizing / MaintenanceEquipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.Containers & Closures Clean, Sterilized, Pyrogen-freeDrug product closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Mar 29, 2019Mar 29, 2019
An inspector documented issues at the facility.
We were unable to connect this 483 form to an FDA inspection designation, but we do know that an inspector filed this form observing problem(s).View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection.View Inspector NotesInspector’s notes summarizing deficiencies observed during an inspection. - Dec 19, 2018Dec 19, 2018Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Sep 11, 2018Sep 11, 2018Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Sep 28, 2017Sep 28, 2017Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.6 citations
Environmental Monitoring SystemAseptic processing areas are deficient regarding the system for monitoring environmental conditions.Calibration/Inspection/Checking not doneRoutine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.Handling and Storage to Prevent ContaminationThere was a failure to handle and store components at all times in a manner to prevent contamination.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Jun 8, 2016Jun 8, 2016Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Nov 21, 2014Nov 21, 2014Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Aug 28, 2014Aug 28, 2014Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Apr 12, 2013Apr 12, 2013Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Jan 20, 2012Jan 20, 2012Inspection
The FDA determined this facility was in an acceptable state.
This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors. - Sep 2, 2011Sep 2, 2011Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.ProPublica was unable to locate a 483 form detailing issues found in this inspection. - Dec 10, 2010Dec 10, 2010Inspection With Issues
The FDA found issues but determined the facility can correct them voluntarily.
In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.ProPublica was unable to locate a 483 form detailing issues found in this inspection.