Rohto-mentholatum (vietnam) Co., Ltd.

This drug manufacturing facility is registered with the FDA by Mentholatum Company, The.

Facility Inspection History

The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.

Note: ProPublica does not provide medical advice. Stopping your medication, doctors warn, can be dangerous. Please consult your doctor first if you have concerns. Read more
4 Known Inspections

The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.

4 Inspections Found Issues

When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.

  • Nov 1, 2019
    Nov 1, 2019
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
  • Mar 16, 2018
    Mar 16, 2018
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
  • Oct 21, 2016
    Oct 21, 2016

    An import ban on the facility lifted some time after this date.

    The FDA doesn't publish a historic record of import alerts, but the last time we saw this facility on archived import bans lists was Oct 21, 2016.
  • Apr 14, 2015
    Apr 14, 2015
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.
  • Aug 26, 2013
    Aug 26, 2013
    Import Ban

    The FDA banned the import of medications from this facility.

    An import alert was issued for this facility, meaning the FDA had reason to believe products manufactured there violated FDA manufacturing standards and should not be allowed into the country.
  • May 15, 2012
    May 15, 2012
    Inspection With Issues

    The FDA ruled the facility was in an “unacceptable state of compliance.”

    Inspectors found serious issues at the facility, and the agency ultimately recommended official compliance action. In cases like this, the FDA typically pauses the facility’s pending drug approvals. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public.
    13 citations
    Aseptic Processing Area
    Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
    Written Procedures Not Followed
    Written procedures are not followed for the receipt and identification of drug product containers and closures.
    Top/Middle/Bottom container sampling
    Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.