Englewood Lab, Inc.

United States See location details

This drug manufacturing facility is registered with the FDA by Englewood Lab, Inc..

Facility Inspection History

The FDA is responsible for inspecting drug manufacturing facilities for violations of good manufacturing practices, such as a lack of documented drug quality testing or contaminated equipment. Below is a timeline of FDA inspections and outcomes for this facility assembled by ProPublica.

Note: ProPublica does not provide medical advice. Stopping your medication, doctors warn, can be dangerous. Please consult your doctor first if you have concerns. Read more
5 Known Inspections

The inspections we were able to locate using available FDA data do not include inspections in advance of the release of a new drug product.

3 Inspections Found Issues

When issues are observed, inspectors usually file an FDA 483 form with citations. In more serious cases, the FDA can issue warning letters or even ban the import of drugs from the facility.

  • Apr 23, 2025
    Apr 23, 2025
    Inspection With Issues

    The FDA ruled the facility was in an “unacceptable state of compliance.”

    Inspectors found serious issues at the facility, and the agency ultimately recommended official compliance action. In cases like this, the FDA typically pauses the facility’s pending drug approvals. There may be additional communications, including about issues being resolved, that are not reflected in our database because they have not been made public.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
    4 citations
    Procedures not in writing, fully followed
    The responsibilities and procedures applicable to the quality control unit are not in writing.
    Cleaning / Sanitizing / Maintenance
    Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
    Component identification test
    Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
    View Inspector Notes
    Inspector’s notes summarizing deficiencies observed during an inspection.
  • Mar 19, 2018
    Mar 19, 2018
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    1 citation
    Written procedures not established/followed
    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.
  • Oct 28, 2015
    Oct 28, 2015
    Inspection

    The FDA determined this facility was in an acceptable state.

    This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors.
  • Apr 23, 2013
    Apr 23, 2013
    Inspection

    The FDA determined this facility was in an acceptable state.

    This is the best possible outcome for an inspection. The FDA took no compliance action and ProPublica found no issues documented by inspectors.
  • Aug 25, 2011
    Aug 25, 2011
    Inspection With Issues

    The FDA found issues but determined the facility can correct them voluntarily.

    In some cases, inspectors may have recommended a different (potentially more serious) classification, but the agency declined to pursue further enforcement at the time.
    5 citations
    Written procedures not established/followed
    Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
    input/output verification
    Input to and output from the computer are not checked for accuracy.
    Reports of Analysis (Components)
    Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
    ProPublica was unable to locate a 483 form detailing issues found in this inspection.