Health
Federal health inspectors from the Centers for Disease Control and Prevention inspect cruise ships twice a year, checking everything from kitchen equipment to dishwasher temperatures, and grade ships based on what they find. A score below 86 is considered failing. Cruise ships are also required to report all illness outbreaks affecting more than 3% of passengers or crew to the CDC. Inspections and outbreaks from 2010 to the present are shown below.
Health Scores & Inspections
93/100
Health Score: Mar 2012
Highest: 99 | Lowest: 93
123
Deficiencies (found in 3 inspections).
Illness Outbreaks
None Reported
Health Scores & Inspections: Details
Inspection on Mar 02, 2012 | Score: 93
Buffet-Veranda Cafe
The written time only as a public health control plan states that undercounter reach-in refrigerators are on temperature control, but they are labeled as time control and managed under time control according to staff.
Buffet-Veranda Cafe
There was no consumer advisory provided in the cafe menu for eggs poached and cooked to order. Additionally, cold-smoked salmon was presented on the buffet line as a ready-to-eat food and there was no consumer advisory posted for that food. This was also noted in the 9 December 2011 VSP report.
Buffet-Veranda Cafe
There was an uncovered plate of fresh fruit on top of the deli buffet which included pears and plums. Directly beside was an uncovered dish of sugar- coated ginger candies all for passenger self-service. Neither was shielded. Staff removed these immediately.
Dining Room-Main Dining Room - Menu
There was a consumer advisory on the various dining room menu's, but there was no marking or asterisk beside the undercooked foods which are served ready-to-eat, either by the recipe of the dish or requesting cooking doneness. This was also noted in the 9 December VSP inspection report.
Galley-Time Control Plan
The written time control plan is not consistent from the procedures side which describes the food flow in the galley and the descriptive page, which simply states that all food in the galley is under time control. The plan does not describe which units are managed under time control and does not mention the various pans on counters which are under ice or not, but contain foods which are ready to use in a dish, condiments, sauces or other mise en place preparations). The flow plan describes foods prepared and held hot in the galley, which move to time control when transferred.
Buffet-Veranda Cafe
At the buffet handwash station were three solution filled buckets with wiping cloths inside. The gray sanitizing bucket had a solution with black dirt particles and cloudy water. When tested with a test strip there was no residual chlorine in this solution. It was immediately removed and dumped.
Buffet-Veranda Cafe
One live fruit fly was observed on the deckhead over the in-service buffet line.
Galley-Veranda Cafe Galley - Dishwash
One of four previously cleaned cutting boards on the clean storage rack was found very soiled with food and oil residue. It was removed for rewashing.
Galley-Veranda Cafe Galley - Dishwash
Three of four previously cleaned cutting boards were scored along the surface from knife marks, leaving a non-smooth surface which was difficult to clean.
Galley-Veranda Cafe Galley - Coffee Station
One live fruit fly was observed on the bulkhead at the coffee station.
Galley-Veranda Cafe Galley - Coffee Station
Gaps were present where the counter model coffee machine power cables and water pipe penetrated the bulkhead thru the side stainless steel panel in the undercounter technical compartment below the machine. This finding was also noted in the 9 December 2011 VSP inspection.
Galley-Main Galley - Dishwash
A dishware rack was set on the deck as a deck stand and a large basket of soiled utensils was stored on top of it.
Food Service General-Ice Machines - Chilled Water
There was no unique identification made of the chilled water piping which was connected beside potable water pipes to the rear panel of the ice machines located in galleys and pantries throughout the food areas of the ship.
Galley-Beverage Counter
There was less than the minimum 110 lux (10 foot candles) of artificial light behind and beside the ice machine.
Galley-Beverage Counter
One live fruit fly was observed at the ice machine.
Galley-Beverage Counter
There was a heavy accumulated layer of dust debris coating the deckhead exhaust vent cover directly above the WMF coffee machine on this counter. Staff cleaned the vent cover during the inspection. Additionally, there was heavy dust debris coating the exhaust air vent cover over the soiled dish landing counter in the adjacent dishwash area.
Galley-Beverage Counter
The milk transfer tubing from the milk refrigerator to the WMF coffee machine was removed and cleaned every 24 hours according to staff. This milk refrigerator was on time control throughout the day, with the pan for milk removed every 4 hours and a clean pan used to replace on that frequency.
Galley-Cold Galley
The previously cleaned meat slicer's lower blade guard was soiled with what appeared to be food residue. In a closer examination it appeared this residue was actually stuck in crevices or pitting of the cast aluminum guard material.
Galley-Cold Galley
The cast aluminum lower blade guard on the counter model slicer appeared to be pitted and no longer smooth for cleaning. Food residue appeared to be present in the crevices of this metal.
Galley-Cold Galley
The ambient air temperature inside the walk-in refrigerator was 45 °F, according to the mounted thermometer inside the unit. The walk-in door was locked for over 25 minutes and the ambient air temperature was 41 °F, according to the mounted thermometer inside. Several foods checked at both times had temperatures of 44-45 °F.
Galley-Cold Galley
A large pan containing several feta cheese blocks in water had a food temperature of 44-45 °F and a large pan of milk and mueslix had a temperature of 44-45 °F inside the walk-in refrigerator. Both products were immediately removed for blast chilling.
Galley-Cold Galley
The artificial light level behind and around the large ice machine and adjacent blast chiller were below the minimum 110 lux.
Food Service General-Galleys - Veranda, Main, and Crew Galleys
The decks were in varying states of repair, with the most common problem being missing or recessed grout either between tiles or along the sides of the gutterways in all the galleys. There were also cracked deck tiles in locations of all the galleys. Sealant was applied heavily along deckhead panels and especially along the profile strips between panels, and some of that was peeling in every galley.
Galley-Main Galley - Dry Store
The decks beneath the storage racks and in the corners of this space were soiled with dirt and food residue.
Galley-Pastry/Bakery
The large supply air vent cover had condensate water drops hanging along the outer ring surface of the perimeter. Water drops were observed on the port food preparation counter directly below this vent. Staff came and cleaned up this water and dried the vent during the inspection.
Galley-Pastry/Bakery
The large supply air vent cover had condensate water drops hanging along the outer ring surface of the perimeter. Water drops were observed on the port food preparation counter directly below this vent. The area was not in use at the time and staff cleaned up this water and dried the vent during the inspection.
Galley-Pastry/Bakery
One live filth fly was observed setting on the side exterior surface of the dough sheeter.
Preparation Room-Provisions Corridor
Four live fruit flies were observed on the deckhead over the food preparation sink.
Preparation Room-Provisions Corridor
There was food debris and dirt residue noted on the bulkhead and deckhead in the butcher shop. The area was previously cleaned and not in use at the time of inspection.
Preparation Room-Provisions Corridor
There were 3 live fruit flies and 1 live filth fly present on the bulkhead and deckhead at the preparation sink in the vegetable preparation room.
Preparation Room-Provisions Corridor
One previously cleaned chef's knife was found soiled with food debris on the blade and stored with clean items on the bulkhead overshelf. The knife was immediately removed for rewashing.
Provisions-Ice Cream Walk-in Freezer
At least three of the filled ice cream packages were damaged and torn along the lid, exposing the top layer of ice cream to contamination. One container was stacked and crushing another container to the point of destroying the outer carton from the lid to a position halfway down the container.
Buffet-Crew Mess - Coffee Station
The power cable to the ice/water dispenser was draped on the counter below. Additionally, the water supply tube to this same dispenser was on the counter in front of the machine.
Buffet-Crew Mess - Coffee Station
The artificial light level behind and around the counter-mounted ice/water and coffee machines was below the minimum 110 lux.
Buffet-Crew Mess - Coffee Station
The toaster oven was mounted to the counter with the lower edge only 1/2 inch above the counter, making cleaning below difficult.
Buffet-Crew Mess - Coffee Station
The paper towel dispenser for the beverage counter handwash station was mounted partially over the adjacent preparation and service counter. Dripped water was observed at this counter and directly below the paper towel dispenser.
Buffet-Crew Mess - Time Control Plan
Staff stated that the buffet line undercounter reach-in refrigerators were on time only as a public health control, but the written and posted time control plan stated that these units were on temperature control.
Buffet-Crew Mess
A small bin of sugar was observed on the top of the buffet overshelf with a spoon inside. The spoon handle was in contact with the sugar.
Buffet-Crew Mess
One filth fly was observed at this buffet circulating around the crew who were serving themselves at the time of inspection.
Pantry-Club Bar Pantry
There was a gap present where the ice machine power cable entered the stainless steel conduit pipe before that pipe penetrated the bulkhead behind. Additionally, there was another gap present where the water pipe from the ice machine penetrated the stainless steel conduit pipe at the deckhead over the machine.
Medical-Viral Collection Containers
The medical staff had a supply of about 20 clinical specimen collection containers for viral agents with an expiration date of June 2010. These were separated for being discarded. After further checking the supplies, more containers were found with expiration dates of March 2013.
Potable Water-Microbiological Monitoring
The UV lamp used for the coliform/E.Coli tests did not work.
Potable Water-Bunkering Records
Since January 27, 2012, there were many instances where the free halogen residual level was not checked within 30 minutes of the start of the bunkering to verify that it was to at least 2.0 mg/L (ppm). Also some charts had follow-up halogen concentrations and pH recordings with hours before the bunkering process actually started. The crew member stated that the time of the recordings were incorrect.
Potable Water-Bunkering
The words 'POTABLE WATER ONLY' on one of the potable water hoses was faded and not legible.
Potable Water-Distillate and Permeate Lines
The distillate water lines from the evaporators to the halogen injection point and the permeate lines from the reverse osmosis plant to the halogen injection point were not striped in accordance with ISO 14726 (blue/gray/blue).
Potable Water-Cross-Connection Control Program
The air-gaps on the filling lines to the compensation tanks of the recreational water facilities were not listed on the cross-connection control program.
Potable Water-RWF Compensation Tanks
The filling lines to the compensation tanks of the recreational water facilities were not striped in accordance with ISO 14726 (blue/green/blue) or blue only.
Potable Water-Minerilizer Drain Line
The mineralizer drain line did not show any form of backflow prevention on the cross-connection control program. When checked locally, the crew member stated that they connect a hose to the drain line of the mineralizer and connect the other end of the hose to a pipe directed to gray water tank. In this procedure, there is not a form of backflow prevention.
Pantry-Deck 4 - Housekeeping Pantry
The ice machine had an equipment/bulkhead clearance of about 2 inches on the back of the ice machine, not allowing enough space for cleaning.
Integrated Pest Management-Mooring Lines
The rat guards installed on the mooring lines were partially open not protecting the lines completely.
Housekeeping-Outbreak Prevention and Response Plan
The outbreak prevention and response plan did not include procedures for informing passengers and crew members of an ongoing outbreak, procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage, or procedures for returning the vessel to normal operating conditions after an outbreak.
Recreational Water Facilities-Analizer Chart Recorders
The sample lines to the analyzer chart recorders for the swimming pool and deck 7 whirlpools were located after the compensation tank. In addition, the sample line for the deck 5 whirlpool could not be verified if it was drawn from before or after the compensation tank.
Recreational Water Facilities-Deck 7 Starboard Whirlpool Records
The charts had a faded or nonexistent line monitoring the pH levels from February 22 to February 27, 2012. There were no manual checks recorded on the charts.
Recreational Water Facilities-Fecal/Vomit Accident Plan
The concentration and time (CT) values in the written fecal and vomit accident plan were not updated to the current values of 1,530.
Inspection on Dec 09, 2011 | Score: 96
Medical-Acute Gastroenteritis Surveillance Log
The acute gastroenteritis (AGE) surveillance log did not include the case identification number for passengers and crew members. Also the log was not in the exact order as required in the 2011 VSP Operations Manual.
Potable Water-Tank Maintenance
The documentation for the inspection, cleaning, and disinfection of tank 2P did not include the free halogen residual level before the tank was placed back into service.
Recreational Water Facilities-Filter Housings
There was no documentation that the cartridge filter housings were cleaned, rinsed, and disinfected before the new filter media was placed in it.
Recreational Water Facilities-Turnover Rates
There was no documentation of the turnover rates for all of the recreational water facilities.
Recreational Water Facilities-Sample Lines
The sample lines for the analyzer chart recorders for the swimming pool, whirlpool 7 port, and whirlpool 7 starboard were located after the compensation tank.
Housekeeping-Outbreak Prevention and Response Plan
The outbreak prevention and response plan indicated that 'guest and crew hand contact surfaces to be cleaned and disinfected with Virox 1:128 every 2 hours - contact time 5 minutes' during outbreak mode.
Housekeeping-Outbreak Prevention and Response Plan
The outbreak prevention and response plan did not include the duties and responsibilities of each department and their staff for all the passenger and crew public areas, procedures for informing current passengers and crew members of the outbreak and those embarking the vessel following an outbreak voyage, or procedures for returning the vessel to normal operating conditions after an outbreak.
Housekeeping-Public Toilet Rooms
The signs on the door of the public toilet rooms advised users to use tissues to open the door, but no tissues were available. Only cloth hand towels were available, but they were not indicated on the signs.
Pantry-Housekeeping
The light intensity was below 110 lux behind and around the ice machines.
Bar-Horizon Bar
The vinyl bulkhead/deck coving was damaged on the corner below the utility sink, making cleaning difficult.
Bar-Sky Bar
The sealant was peeling along the top of the coved tiles below the undercounter refrigerators and technical compartment, exposing gaps and seams.
Pantry-Club Bar
There was no coving at the dry store locker/deck juncture. Staff stated this was scheduled for the November 2012 dry dock.
Recreational Water Facilities-Hair and Lint Strainers
There was no documentation that the hair and lint strainers were cleaned, rinsed, and disinfected weekly.
Room Service-Pantry
The locker containing cleaning chemicals was not labeled 'cleaning materials only.'
Food Service General-Lighting
The lighting behind and around several pieces of counter-mounted and deck-mounted equipment was less than 110 lux in several areas, including the deck 5 room service pantry, crew galley, main galley, pastry, and coffee stations.
Food Service General-Consumer Advisory
Some of the menus did not contain the consumer advisory statement. Also, animal-derived foods, such as fish, eggs, and steaks, that could be served undercooked or cooked to order in the Veranda Cafe, main galley, and room service were not identified on the menus with an asterisk as being of risk.
Buffet-Coffee Station
The upper and lower portions of the plastic ice chute for the ice dispenser were worn and cracked.
Food Service General-Time Control
In the main galley, pastry, lido, and crew galley, the refrigeration and hot holding units identified in the time control plans as being on time control were not physically labeled.
Provisions-Fruit Fridge #9
The coving was worn and cracked in several areas. Also, there were several loose tiles where the grouting had separated from the tile.
Food Service General-Lighting
The light intensity was less than 220 lux on the preparation counter on the worker side of the cold buffet in the crew mess and in the equipment storage room in the crew galley. Also, all five waiter stations in the main dining room had less than 220 lux at maximum light. In addition, the lighting was less than 220 lux in front of the WMF coffee machine adjacent to the lido galley and on the beverage station counter adjacent to the lido buffet and galley.
Preparation Room-Meat Thawing Fridge
One pan of raw pork was partially below three pans of raw poultry. The pork was moved to an appropriate location.
Galley-Equipment Room
There was no bulkhead/deck coving. Several pieces of food equipment were stored in this area.
Galley-Equipment Room
Several pieces of clean food preparation equipment, such as pots, pans, and bowls, were stored on the deck.
Buffet-Lido
The glass temperature gauge for undercounter refrigerator #6 was cracked and the protection for the indicator light for the refrigerator was missing.
Buffet-Lido
The power cord from the toaster oven was draped across the counter top, making cleaning difficult.
Dining Room-Crew
The cleaning locker between the crew dining room and the crew buffet was not labeled 'cleaning materials only.'
Food Service General-Refrigerator Door Gaskets
The door gaskets on several of the undercounter and reach-in refrigerators were loose, worn, and cracked. This made closing the units very difficult and allowed warm air to enter the units. This was observed on the crew dining room officer refrigerator, deck 5 Amundsen pantry undercounter refrigerator #13, crew galley undercounter refrigerator #4, and main galley undercounter refrigerators behind the coffee station. According to the staff, work orders were placed in August and September 2011 for these units.
Galley-Deli Slicer
The horizontal plastic piece on the deli slicer used to protect workers was cracked and chipped in several places.
Dining Room-Waiter Stations
Soft sealant was used for coving at the waiter station/deck junctures in the main dining room.
Galley-Coffee Station
A coffee carafe was heavily soiled and stored inverted in a clean dish storage cabinet. The carafe was removed.
Galley-Warewashing
Condensation was collecting on all of the air supply vents and bulkheads and was dripping onto the deck between the coffee station and the handwashing station at the soiled end of the in-use flight-type warewash machine. No clean items were impacted.
Galley-Coffee Station
There was a hole and a gap leading to a void space where the pipe penetrated the stainless steel panel between the adjacent technical compartments below the coffee machine.
Galley-Coffee Station
There were gaps leading to void spaces where the two pipes penetrated the stainless steel panel between the adjacent technical compartments below the coffee machine.
Buffet-Lido
Soft sealant was used for coving at the buffet/deck juncture on the passenger side of the buffet.
Dining Room-Lido
The wooden frame at the bottom of the tea cabinet was worn and had several cracks and crevices.
Dining Room-Lido
The wooden frame at the bottom of the tea cabinet was heavily soiled with a sticky residue.
Galley-Deck 4 Crew Toilet Rooms
The male and female crew toilet rooms outside the galley did not contain signs stating 'wash hands after using toilet.' These toilet rooms were used by food employees.
Galley-
Soft sealant was used for coving at the bulkhead/deck juncture between the beverage station and the coffee station at the entrance to the galley. A bulkhead-mounted wooden baseboard above the coving was worn, cracked, creviced, and had open screws, making cleaning difficult.
Galley-Pastry
There were four slotted fasteners in the food splash zone of the counter-mounted mixer and eight slotted fasteners in the food splash zone of the deck-mounted mixer.
Pantry-Amundsen
A worker was observed preparing several drinks on the soiled landing of the warewashing area that was labeled 'dirty.' A tray of condiments was also stored directly on the soiled landing along with an ice bin and champagne bottles. The worker moved all items to the preparation counter.
Galley-Pastry
The table-mounted flat top burner was measured at three inches above the table. The horizontal distance of the table below the flat top burner was greater than 20 inches from the point of access for cleaning.
Buffet-Lido
The indicator light for undercounter refrigerator #6 was heavily soiled with dust.
Galley-
The soft sealant coving at the bulkhead/deck juncture between the beverage station and the coffee station at the entrance to the galley was soiled.
Inspection on Mar 19, 2010 | Score: 99
Pantry-Deck 4 - Room Service
The ice machine was mounted approximately 2-3 inches from the bulkhead, making access for cleaning difficult.
Pantry-Deck 4 - Room Service
The ledge on the back of the ice machine was heavily soiled.
Potable Water-Bunkering
One chart record out of the last 15 days indicated that the vessel bunkered water at less than 2 PPM free halogen for 3 hours. There was no notation of equipment problems or that any action was taken.
DO NOT USE (whirlpool/spa)-
The drain covers and suction fittings for all three whirlpool/spas, as well as the swimming pool, did not appear to meet the ASME/ANSI A112.19.8M standard. There was no documentation on board for the covers. There were new covers drain covers on board that meet the standard only for the whirlppols/spas.
DO NOT USE (whirlpool/spa)-Strainers
The hair strainer cansiters were corroded and did not appear to have been opened in months.
Potable Water-Mineralizer
The newly installed reduced pressure type back flow prevention device had not been tested.
Potable Water-Fan Room 570
There were no backflow prevention devices on the hot and cold potable water lines. The lines had threaded connections.
Potable Water-Fan Room 570
The potable water lines were not striped blue.
Bar-Horizon Bar
The deck material behind the bar was vinyl. The vinyl was damaged at the cove turn.
Pantry-Club
There was no coving under the dry store locker at the deck/bulkhead juncture.
Food Service General-
There were cracked deck tiles and recessed or missing grout in the food preparation and provisions areas.
Buffet-Lido
The deck counter juncture of the cold top was not coved at the service side of the counter.
Galley-
The galley elevator was not coved in the back right corner. The rail guide for the door was extremely soiled and was filled with standing water.
Galley-Equipment Room
There was no coving along the deck/bulkhead juncture in this room.
Galley-Dishwash
There were two unsealed penetrations through the deckhead around the water lines supplying the ice machine across from the dishwash area.
Galley-Beverage Area
There was a leak at the connection for the bucket fill at the handwash station behind the beverage counter.
Galley-Dishwash
The data plate for the conveyor rack dishwash machine was for a hood type dishwash machine. The data plate had a wash cycle time, dwell time and final rinse cycle time. The conveyor machine does not have these cycles and should mention the transit time per rack.
Galley-Dishwash
The conveyor rack dishwash machine was producing steam at the final rinse area of the machine. The plate surface temperature when measured with the inspector's measuring device was 173° F.
Galley-Dry Stores
Soft sealant was used as grout in this area. The sealant was extremely soiled and peeling.
Galley-Pastry
There was an unlabeled bulk bin of multi-grain flour in this area.
Galley-Pastry
The dough sheeter belt was soiled and damp.
Galley-Pastry
There was a black slimy substance on the guiding wheel of the dough sheeter.
Galley-Hot Galley
There were no backflow prevention devices installed on the potable water lines supplying the combination ovens. These ovens had spray hoses attached.
Galley-Time As a Public Health Conrtrol
The warming unit under the microwave was not mentioned on the time as a public health control plan. The plan stated that all hot hold units were on temperature control. Per staff, this was not a hot holding unit and was on time control.
Galley-
The entrance to the crew galley had a void in the door frame where the latching pin inserted.
Galley-
The entrance to the lido galley had a void in the door frame where the latching pin inserted.
Safety
Serious crimes and injuries on cruise ships that make port in the U.S. are required to be reported to the Coast Guard. Smaller-scale crimes and thefts are reported to local police authorities (if reported at all). Incidents and inspections from 2010 to the present are shown below.
Crimes & Incidents
None Reported
Coast Guard Inspections
3
Deficiencies (found in 1 inspections).
Coast Guard Inspections: Details
Inspection on Dec 09, 2011
Construction/Loadline
0710 - It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. All fire doors are only able to be closed on one side of the door. 74 SOLAS (81) II-2/30.3
Fire Fighting
0710 Fire doors in main vertical zone bulkheads and stairway enclosures...shall be of the self-closing type and capable of closing against an inclination of 3.5 degrees opposing closure. Fire door 340 (double leaf door in main passenger stairway) does not close automatically when the local door release is activated. 74 SOLAS (81), II-2/30.4.
Construction/Loadline
0999 - The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. Approximately 80% of the fire doors tested closed at a rate that could cause injury to a person in the way of the door (less than 2 seconds). 74 SOLAS (81) II-2/30.4
Crimes & Incidents: Details
CREDITS & SOURCES
Illustrations: Josh Cochran, special to ProPublica. Data: Coast Guard Port State Information eXchange, Coast Guard Incident Investigative Reports, Coast Guard Marine Casualties & Pollution Data, IMO GISIS Marine Casualties, CDC Inspections & Deficiencies, CDC Outbreaks, CruisePage Man Overboard List, Local crime reports gathered by reporters Lynn Walsh & Dan Krauth, other local crime reports. Photos: VesselFinder. Icons: Jessica Lock, Juan Pablo Bravo,Hans Gerhard Meier.